Confidential Information System Integration Qualification CEIDI for Shielded Room Construction

文章出处:Technology|阅读量:373|发表时间:2021-04-07

Secret-related system integration qualifications refer to the qualifications required for entities engaged in secret-related system business to engage in activities involving state secrets and the ability to keep state secrets. The "integration of secret-related systems" here includes the planning, design, development, implementation, service and guarantee of secret-related system projects. Confidential information system integration business types include: system integration, system consulting, software development, integrated wiring, security monitoring, shielding room construction, operation and maintenance, data recovery, project supervision, and other businesses reviewed and approved by the national security administrative department. Today, let's take a look at the comparison of application conditions for applying for level A and B for secret information system integration qualification. In our country, large-scale state-owned organizations such as the People's Liberation Army Armed Police Force will have quite a few shielded computer room construction projects, and companies that build such computer rooms need to have the following qualifications:

I. Grade A qualification

1. The actual paid-up amount of registered capital in monetary funds shall not be less than RMB 10 million.

2. The total amount of revenue from the construction of shielding rooms and the sales of shielding products in the past three years is not less than 30 million yuan.

3. There are no less than 50 relevant personnel engaged in the construction of shielded rooms, and no less than 40 persons who have paid social security in the unit for more than one year according to law.

4. At least 2 persons with senior professional titles or practicing qualifications in the field of electromagnetic field and microwave recognized by human resources and social security departments or their authorized agencies at or above the provincial level, of which no less than 1 persons have paid social security for more than one year in their own unit according to law name.

5. Secret-related business premises with self-owned property rights or lease term of 3 years or more, with an area of no less than 100 square meters, implement closed management, and the surrounding environment is safe and controllable, and are equipped in accordance with national confidentiality regulations and standards. Use necessary technical protection facilities and equipment.

6. Have a fixed processing and production site and special equipment, have the conditions and capabilities of shielding room design, manufacturing, installation, testing, etc., and have self-developed shielding products.

II. Class B qualification

1. The actual paid-up amount of registered capital in monetary capital shall not be less than RMB 3 million.

2. The total amount of revenue from shielding room construction and shielding product sales in the past 3 years is not less than 5 million yuan.

3. There are no less than 20 relevant personnel engaged in the construction of shielded rooms, and no less than 16 persons who have paid social security in the unit for more than one year according to law.

4. At least one person with senior professional titles or practicing qualifications in the field of electromagnetic fields and microwaves recognized by the human resources and social security departments or their authorized agencies at or above the provincial level, of which no less than one person has paid social security for more than one year in the unit. name.

5. Secret-related business premises with their own property rights or lease term of 3 years or more, with an area of no less than 50 square meters, implement closed management, and the surrounding environment is safe and controllable, and are equipped in accordance with national confidentiality regulations and standards. Use necessary technical protection facilities and equipment.

6. Possess the conditions and capabilities of shielding room design, manufacturing, installation, and testing.

Design and construction basis of shielding room

1. "Measurement method of shielding effectiveness of high-performance shielded room" GB12190-90

2. "General technical requirements testing for military shielded computer rooms" GJB20219-94

3. "Code for Construction and Acceptance of Electromagnetic Shielding Room Engineering" SJ31470-2002

4. "Code for Design of Electronic Computer Room" GB50174-93

5. "Computer site safety requirements" GB9361-88

6. "Technical Requirements for Computer Sites" GBGR2887-2000

7. "Technical requirements and measurement methods for electromagnetic shielding of confidential information" BMB3-1999

8. "Design Code and Special Standard for Automatic Fire Alarm System" GB50116-98

9. Relevant electromagnetic compatibility technology principles and current national security regulations.