Congratulations on the approval of the laboratory decoration design plan of an electronics factory in Suzhou. At the end of last year, CEIDI Xidi communicated fully with the person in charge of the project, and patiently revised the design plan (including plane, fire protection, etc.), and finally passed the review.

I. Standard parameters of electronic laboratory purification:

II. General structural materials for electronic laboratories:
1. The return air duct is made of hot-dip galvanized sheet, with flame-retardant PF foamed plastic sheet with good purification and heat preservation effect.

2. The high-efficiency air outlet uses a stainless steel frame, which is beautiful and clean, and the perforated mesh plate uses a painted aluminum plate, which is not rusty and dust-free, and should be cleaned.

3. The ground can use epoxy self-leveling floor or high-grade wear-resistant plastic floor. Anti-static type can be used if anti-static requirements are required.

4. The walls and roof panels of the purification plant are generally made of 50mm thick sandwich color steel plates, which are characterized by beautiful appearance and strong rigidity. The arc wall corners, doors, window frames, etc. are generally made of special alumina profiles.

III. CEIDI Xidi Electronics Factory/Electronic Laboratory Purification Air Conditioning Solution

Option 1: At present, it is the most traditional purification air conditioning design. The combined air handling unit contains various functional sections, such as primary filter section, mixing section, surface cooling section, medium efficiency filter section, secondary return air (or intermediate section) humidification section, heating section, fan section, etc. The cold source is mainly provided by the chiller.

Scheme 2: Compared with scheme 1, scheme two is a relatively simple clean air conditioning design scheme. Not only can the area of the machine room be greatly reduced, but also the water-cooled cabinet can be arranged in a smaller purification workshop or machine room according to the specific situation. At the same time, the pressurized air cabinet can be arranged in the machine room or suspended in the machine room or in the machine room. Inside the mezzanine.

Scheme 3: Mainly used in dust-free workshops that do not require high indoor temperature and humidity accuracy, and is the simplest air conditioning scheme. The split air-conditioning cabinet can be directly arranged in the workshop, and surrounded by color steel, and the return air vent (with primary effect filter) is opened on the color steel plate at the return air outlet of the cabinet; the fan filter unit FFU is evenly arranged on the ceiling smallpox.